
- #Dometic weatherpro auxiliary power cable how to#
- #Dometic weatherpro auxiliary power cable download#
Move the sensor away from the flue tube (red) and pack fiberglass insulation between theįlue tube and the ARP Boiler sensor. The ARP Boiler Sensor is clipped onto the boiler tube (black), orient the clip so that it snapsĪround the back of the tube. Please note that the boiler tube (black) is behind This is a simplified drawing of the tubes inside the boiler housing. Also, it is a good idea to either use an in-line fuse or an ARPĬircuit Breaker in-line with the power supply to the control box. This is the Dometic control box, see (3) for wiring.

The ARP yellow wire is connected to the screw terminal where the power wire was removed in the last step.

Remove the positive lead from the screw terminal and connect it to the ARP red wire. The ARP is shown spliced into the power wire, where the ARP red wire is connected to the power source coming from the RV battery. The ARP ground is the green wire, the green wire may be connected either to the screw terminal, or the ground lug next to the screw terminal (2) on the sheet metal plate that the control box is mounted on. The next step is to connect the ARP ground. The ARP must be wired in-line with the +12VDC going from the screw terminal into theĬlick for Further Reading on ARP FunctionĪlways start wiring by disconnecting the power to the fridge, this can be done by removing the fuse. Power wires vary by RV manufacture it is up to the installer to determine theĬorrect wire color for the power and ground.Īll Dometic fridge have a screw terminal where the power and ground wires are routed from Please note that two wires willĮnter the cooling unit compartment, one power and the other ground. Starting at the RV, the RV delivers power to run the fridge and its controls. RM2852 ANY 2-WAY DOMETIC WITHOUT RECALL Wiring Scheme Number 1 (no thermal switch).NDR1292, NDR1492 Scheme 9 (Thermal-Switch 2-way).NDA1402, NDA 1402, & Early 3-Way Scheme 7 (High Amperage).RM1350, RME1350, OTHER FRIDGE WITH DOOR LOCK FUNCTION Scheme 6 (Door Lock Function).RM3663, some RM3863, & MANY MORE ♥ Scheme 4 (3-way Early).DMR702, OTHER NEWER MODELS ♥ Scheme 3 (2-way Late).Please scan the wiring schemes, if your fridge is not listed please use the Contact Us form.Ĭlick the link to the right to go directly to the wiring drawing for your Instructions: Some of the models of Dometic fridge are listed on the left, EACH VERSION OF CONTROL HAS INTRICACIES REQUIRING THE WRITTEN
#Dometic weatherpro auxiliary power cable download#
REQUIRED TO DOWNLOAD INSTALLATION INSTRUCTIONS - WEB PAGES ARE SUPPLEMENTAL Each wiring scheme is numbered for ease ofĬommunication if telephone or e-mail installation assistance is needed. The following Dometic wiring schemes are provided so that the installer can

To view how the boiler maintains a constant temperature, or overheats, click here to view video. The cooling unit boiler temperature when installed, maintained, and operated The Fridge Defend addresses one of the rootĬauses of RV fridge failure which can result in a fire, theĬooling unit boiler overheating. One fact is evident, the recalls were not totally effectiveīecause the failures continued. As as a result, recalls of the refrigerators The majority of these failures were located in
#Dometic weatherpro auxiliary power cable how to#
Recalls enabling one to determine how to wire the Fridge Defend Control.Īround the year 2000 Dometic refrigerators started developing problems that This page shows the different Dometic wiring schemes along with the Your Dometic fridge does not come from the factory with adequate boiler temperature
